The labour of disconnecting the old rail and fixing the new one to connection pipes already in place costs from €80. The unit itself, adapters, welding and isolating the riser are not part of this job.
The maker's permission for a hot water connection
The manufacturer Zehnder states about its radiators that they may be connected only to an indirect central heating system, not to the domestic hot water supply. In an indirect system heating water circulates in the rail and does not mix with tap water. Domestic hot water is the same water that comes from the tap, and not all rail materials are designed to be in contact with it.
In older blocks of flats the towel rail is sometimes connected to the hot water pipe. If that is the case in your flat too, read the manual of your chosen model before buying: does the maker allow connection to domestic hot water? If the manual forbids it, look for another model instead of adapting the connection.
Zehnder technical data sheet, checked on 25 November 2026. This is one manufacturer’s requirement for its own models; rules of other makers may differ.
Chrome or powder coat, valves and heating water
The manufacturer TERMA gives several points about its water radiators that you need to know before buying. TERMA does not allow towels or clothes to be dried on a chrome-plated radiator; the powder-coated version is meant for drying. No load over 5 kg may be placed on the radiator.
- System
- closed central heating with steel pipes, or plastic pipes with an oxygen diffusion barrier.
- Heating fluid
- free of ethylene glycol or propylene glycol.
- Valves
- TERMA advises them on both flow and return, so the radiator can be disconnected from the heating without draining the system.
If the old rail has no valves, they can be fitted along with the replacement; valves are a separate part. TERMA’s requirements apply to its own radiators, and rules of other makers may differ.
A nickel-plated galvanised rail on the hot water pipe
Annex 2 to Cabinet Regulation No. 907 gives an average standard service life of 30 years for nickel-plated towel rails of galvanised pipe on hot water pipework. The figure is used for planning building repairs; it does not mean a rail has to come off after 30 years.
If the old rail is welded to the pipe rather than screwed on, replacing it may mean cutting and welding. Welding is not part of the price from €80. If the rail is connected to a shared house pipe, shutting that pipe off has to be agreed with the building manager, and this too is separate.
If the rail sits on the building's shared pipe
In a multi-flat building your rail can be fed by a pipe that serves the neighbours as well. If it has no stop valves of its own, it cannot be removed while there is water in that pipe. The pipe can be drained only after the building manager has shut it off. Isolating the riser is not part of the price from €80, and its timing is agreed in advance.
If the rail has its own stop valves, it can be replaced without shutting off the house pipe. Whether they close fully can only be seen on site: an old valve not turned for years may not hold water.
After connection to the heating circuit
If the rail is connected to the heating system, Zehnder states that after connection it is filled, bled, started up and the joints are checked for leaks. Air left in the new rail can stop it warming, so bleeding is part of the start-up.
- Water model
- connects to the existing pipes, and the spacing between them matters.
- Electric model
- no water pipes are needed, but a suitable socket or electrical connection is.
- Pipe spacing
- if the connections of the new rail do not match the old ones, adapters are needed at extra cost.