If a radiator leaks or stays cold, the price depends on whether the fault is in the valve, the thermostat or a joint, whether water has to be drained and whether the part is available. To find out what needs doing, the radiator has to be looked at on site; a home visit with an inspection costs from €40, while the repair and parts are extra.
Unscheduled repair while the heating is on
Cabinet Regulation No. 907 on the survey and repair of residential houses sets out when a house gets an unscheduled repair, meaning one outside the plan. Sub-point 17.12 of the regulation lists damage to the heating system during the heating season as a reason for it. So a leaking radiator in January is not a job to leave until summer.
Source: sub-point 17.12 of Cabinet Regulation No. 907 (likumi.lv, viewed on 25 November 2026). In a block of flats such a repair is usually organised by the building manager, unless the house documents say otherwise.
In practice this means two things. First, if the damage affects the building’s part of the heating, the manager needs to know, because removing a radiator or shutting a riser usually needs their consent. Second, if the fault is only in the radiator valve or a joint, it may be possible to fix it without shutting off the whole building. That can only be judged at the radiator itself.
A valve pin stuck over summer
Not every cold radiator is broken. For example, a Finnish advice article explains that a cold radiator is often caused by the valve pin behind the thermostatic head. This small metal pin sticks in summer, when the head stays closed for a long time. To free it, the article suggests pressing it or lightly tapping the side of the valve. It is a practical tip, not a standard, and if the pin does not move or the valve starts dripping, call the plumber.
If the pin moves but the radiator still stays cold, the fault may be air, a blockage or the building system. There is more on this on the page about a radiator not heating.
Leaks, draining the water and parts
When the water has to come out
If a radiator joint leaks or the valve has to be replaced entirely, water usually has to be drained from the radiator or riser. In a block of flats this is agreed with the building manager, and the timing and price of the work depend on it.
When the part cannot be bought
Spare parts may no longer exist for older valves and thermostats. The repair may then mean replacing the whole valve, and installing a thermostatic valve becomes a separate job.
Bleeding with the supplied plug
For its panel radiators the manufacturer Kermi permits bleeding only through the bleed plug supplied in the kit, which must not be swapped for another shop-bought one. Kermi also explains why bleeding continues for a moment after water starts flowing: the plug frees the radiator panels one after another. Hot water can scald, so hold a container or cloth under the plug and protect your hand.
Kermi advises bleeding a radiator after it is put into use and after longer breaks in operation, with an ordinary radiator key. In a block of flats on central heating, air in a radiator may also be a matter of the building system, and the manager then needs to know about it.
Valve body and thermostatic head
A thermostatic valve has two parts. The body is screwed into the pipe and is permanently full of water. The head sits on top and, as the room temperature changes, presses the valve pin, opening or closing the flow. The head can come off without draining water, but changing the body requires the radiator to be isolated and drained.
That makes installing a thermostatic valve in place of an old plain one a bigger job than changing a head. In a block of flats it is usually agreed with the building manager, because the valve body is linked to the building heating system.
For example, the instructions for a HUMMEL Design thermostatic head say to turn the head to position 5, fully open, before fitting, and only then to tighten it with the M 30 x 1.5 nut. The head should not be mounted pointing upwards, as it then does not regulate accurately. The procedure may differ for other heads.
Cleaning the radiator surface
If you want to clean the dust off after a repair, the manufacturer Purmo states that the radiator should be cleaned with a solution of household detergent, without products containing ammonia or abrasives.