A radiator not heating, or heating less than you expect, is not necessarily broken just because it is lukewarm.

Advice article, updated 25 November 2026. References: 5.

Book a visit See the rates

Once your form is in, we contact you within 5 minutes.

Illustration: a new panel radiator under a window with the removed cast-iron one standing in front

Ask for a plumber to come

Once you send the form, we contact you within 5 minutes

By submitting this form, you agree to our privacy policy.

For example, the Helsinki rental housing company Heka explains to its residents that in autumn, when it is around 10 degrees outside, water at about 30–35 degrees circulates in the radiators. So it may not feel warm to the hand, yet it still warms the room.

How a properly working radiator feels

Heka also describes how a fault-free radiator behaves: it is warmer at the top than at the bottom, warmest right after the thermostat, and you hear no hissing or gurgling in it. It is a handy comparison, because you can check it by hand without unscrewing anything.

If yours behaves differently, for instance something hisses or gurgles in it, or the warmest spot is not by the thermostat, that does not yet say where the fault is. It is a reason to inspect the radiator, not to replace it at once.

When judging a radiator, consider the weather. A hard frost with a radiator still barely lukewarm is a different case from a lukewarm radiator on a mild October day, when the 30–35 degree water Heka describes is normal.

A thermostat left in one position all summer

Heka advises turning the radiator thermostat from closed to open at least a couple of times a year so that the thermostat and valve do not stick. If it has stood closed for months, it may not open by itself in autumn, and the radiator stays cold although the heating in the house is already on.

The thermostat head is turned by hand. In a house with shared heating, opening valves and bleed screws with tools is not advisable, as the system holds pressure and hot water.

Heka is the City of Helsinki’s rental housing company; its advice to residents is an example, not Latvian rules. Viewed on 25 November 2026.

If the whole flat is cold, not just one radiator

In a block of flats with shared heating, a temperature complaint is the building manager’s matter. An LV portāls e-consultation (2025) explains that the manager must answer owners' complaints, carry out a check and draw up a temperature measurement report. If one flat has +12 °C and another +19 °C, the heating system must be balanced. The same explanation, citing the Ministry of Economics, says regulations set no minimum or maximum temperature for the heating season; the manager sets the regime within their authorisation, or the community of flat owners does.

An LV portāls e-consultation (2016) advises sending the manager a written application with the facts on temperature, asking for an explanation and a solution. If neighbours have the same, a joint complaint can be written, and the manager must reply. Useful in the application are the room temperature with date and time, and which radiators warm and which do not.

When hissing or a cold spot is a plumber's job

The price list has no single starting sum for radiator repair or releasing air, because the scope differs each time. For repair, the sum depends on whether the fault is in the valve, thermostat or a joint, whether water must be drained and whether the needed part is available.

Air in the system often makes itself known at the start of the heating season. SIA “Rīgas namu pārvaldnieks” explained in 2018 that disruptions in house heating systems often arise after heating starts and the system has to be bled, usually even more than once. So gurgling in October does not yet mean a broken radiator.

The sum for releasing air depends on how many radiators must be visited, whether the top floor flat can be accessed and whether pressure then has to be topped up. If a radiator needs replacing altogether, it has its own page: radiator replacement.

If a radiator or its joint leaks, point 23.9 of Cabinet Regulation No. 876 applies. In a breakdown with a leak of heating water, the heat user must immediately disconnect the damaged pipes or heat-using installations and inform the supplier. In a block of flats the user is usually the manager or the community, so a resident tells the manager first. If it can be done safely, keep a container under the leak and mop water off the floor, remembering that it may be hot.

The published rate for this job

Labour charges only, without parts or materials. Rates looked over on 25 November 2026.

  • Putting a leaking or cold radiator right the sum depends on where the fault is and the part by scope
  • Releasing an air lock from the heating the sum depends on the number of radiators and access by scope

About lukewarm radiators

The radiator gurgles but gets warm. Is that a fault already?

According to Heka’s description, no gurgling is heard in a properly working radiator. One possible cause is air in the system. If the house has shared heating, it is worth telling the manager first or requesting an inspection.

In October the radiator is barely warm but the room is not cold. Does it need repair?

Most likely not. If the room holds its warmth, a lukewarm radiator on a mild autumn day is exactly what Heka describes as normal. Think about a fault when the room stays cool even in frost.

A radiator behaving out of the ordinary

A few sentences will do: where it drips, what is blocked or which fixture you want fitted.

Once your form is in, we contact you within 5 minutes.

Ask for a plumber to come

Once you send the form, we contact you within 5 minutes

By submitting this form, you agree to our privacy policy.

Book a visit we contact you within 5 minutes